#sudo smartctl --all /dev/sda

=== START OF INFORMATION SECTION ===
Model Family:     Western Digital Scorpio Blue Serial ATA
Device Model:     WDC WD2500BEVT-22ZCT0
Serial Number:    WD-WXE409H69088
LU WWN Device Id: 5 0014ee 258022f12
Firmware Version: 11.01A11
User Capacity:    250,059,350,016 bytes [250 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    5400 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS (minor revision not indicated)
SATA Version is:  SATA 2.5, 3.0 Gb/s
Local Time is:    Tue Jul 18 21:28:14 2017 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever
                                        been run.
Total time to complete Offline
data collection:                ( 7500) seconds.
Offline data collection
capabilities:                    (0x7b) SMART execute Offline immediate.
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new
                                        command.
                                        Offline surface scan supported.
                                        Self-test supported.
                                        Conveyance Self-test supported.
                                        Selective Self-test supported.
SMART capabilities:            (0x0003) Saves SMART data before entering
                                        power-saving mode.
                                        Supports SMART auto save timer.
Error logging capability:        (0x01) Error logging supported.
                                        General Purpose Logging supported.
Short self-test routine
recommended polling time:        (   2) minutes.
Extended self-test routine
recommended polling time:        (  90) minutes.
Conveyance self-test routine
recommended polling time:        (   5) minutes.
SCT capabilities:              (0x303f) SCT Status supported.
                                        SCT Error Recovery Control supported.
                                        SCT Feature Control supported.
                                        SCT Data Table supported.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x002f   200   200   051    Pre-fail  Always       -       3232
  3 Spin_Up_Time            0x0027   185   184   021    Pre-fail  Always       -       1733
  4 Start_Stop_Count        0x0032   093   093   000    Old_age   Always       -       7637
  5 Reallocated_Sector_Ct   0x0033   200   200   140    Pre-fail  Always       -       0
  7 Seek_Error_Rate         0x002e   100   253   000    Old_age   Always       -       0
  9 Power_On_Hours          0x0032   075   075   000    Old_age   Always       -       18633
 10 Spin_Retry_Count        0x0033   100   100   051    Pre-fail  Always       -       0
 11 Calibration_Retry_Count 0x0032   100   100   000    Old_age   Always       -       0
 12 Power_Cycle_Count       0x0032   094   094   000    Old_age   Always       -       6637
192 Power-Off_Retract_Count 0x0032   200   200   000    Old_age   Always       -       362
193 Load_Cycle_Count        0x0032   091   091   000    Old_age   Always       -       327263
194 Temperature_Celsius     0x0022   107   087   000    Old_age   Always       -       40
196 Reallocated_Event_Count 0x0032   200   200   000    Old_age   Always       -       0
197 Current_Pending_Sector  0x0032   199   199   000    Old_age   Always       -       42
198 Offline_Uncorrectable   0x0030   100   253   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x0032   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x0009   100   253   051    Pre-fail  Offline      -       0

SMART Error Log Version: 1
ATA Error Count: 3054 (device log contains only the most recent five errors)
        CR = Command Register [HEX]
        FR = Features Register [HEX]
        SC = Sector Count Register [HEX]
        SN = Sector Number Register [HEX]
        CL = Cylinder Low Register [HEX]
        CH = Cylinder High Register [HEX]
        DH = Device/Head Register [HEX]
        DC = Device Command Register [HEX]
        ER = Error register [HEX]
        ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 3054 occurred at disk power-on lifetime: 18612 hours (775 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 07 9b 0f 40  Error: UNC at LBA = 0x000f9b07 = 1022727

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 b0 00 9b 0f 0a 08      01:01:54.998  READ FPDMA QUEUED
  60 08 a8 38 9e 0f 0a 08      01:01:54.991  READ FPDMA QUEUED
  60 08 a0 30 9e 0f 0a 08      01:01:54.991  READ FPDMA QUEUED
  60 08 98 28 9e 0f 0a 08      01:01:54.991  READ FPDMA QUEUED
  60 08 90 20 9e 0f 0a 08      01:01:54.991  READ FPDMA QUEUED

Error 3053 occurred at disk power-on lifetime: 18612 hours (775 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 07 9b 0f 40  Error: UNC at LBA = 0x000f9b07 = 1022727

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 f0 00 9b 0f 0a 08      01:01:51.679  READ FPDMA QUEUED
  ef 10 02 00 00 00 00 08      01:01:51.679  SET FEATURES [Enable SATA feature]
  27 00 00 00 00 00 00 08      01:01:51.678  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 00 08      01:01:51.676  IDENTIFY DEVICE
  ef 03 46 00 00 00 00 08      01:01:51.676  SET FEATURES [Set transfer mode]

Error 3052 occurred at disk power-on lifetime: 18612 hours (775 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 07 9b 0f 40  Error: UNC at LBA = 0x000f9b07 = 1022727

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 90 00 9b 0f 0a 08      01:01:48.560  READ FPDMA QUEUED
  ef 10 02 00 00 00 00 08      01:01:48.560  SET FEATURES [Enable SATA feature]
  27 00 00 00 00 00 00 08      01:01:48.560  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 00 08      01:01:48.558  IDENTIFY DEVICE
  ef 03 46 00 00 00 00 08      01:01:48.558  SET FEATURES [Set transfer mode]

Error 3051 occurred at disk power-on lifetime: 18612 hours (775 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 07 9b 0f 40  Error: UNC at LBA = 0x000f9b07 = 1022727

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 70 00 9b 0f 0a 08      01:01:45.172  READ FPDMA QUEUED
  60 08 68 f8 9a 0f 0a 08      01:01:45.172  READ FPDMA QUEUED
  60 08 60 f0 9a 0f 0a 08      01:01:45.172  READ FPDMA QUEUED
  60 08 58 e8 9a 0f 0a 08      01:01:45.172  READ FPDMA QUEUED
  60 08 50 e0 9a 0f 0a 08      01:01:45.172  READ FPDMA QUEUED

Error 3050 occurred at disk power-on lifetime: 18612 hours (775 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  40 51 00 df 9c 1d 40  Error: UNC at LBA = 0x001d9cdf = 1940703

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  60 08 50 d8 9c 1d 0a 08      01:01:38.594  READ FPDMA QUEUED
  e5 00 00 00 00 00 00 08      01:01:38.592  CHECK POWER MODE
  ef 10 02 00 00 00 00 08      01:01:38.592  SET FEATURES [Enable SATA feature]
  27 00 00 00 00 00 00 08      01:01:38.592  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 00 00 00 00 08      01:01:38.590  IDENTIFY DEVICE

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.